安全信息
RTECS | UQ4150000 |
WGK Germany | 1 |
Personal Protective Equipment |
Eyeshields, Gloves, type N95 (US), type P1 (EN143) respirator filter |
Signal word |
|
Precautionary statements | |
- P262 Do not get in eyes, on skin, or on clothing. 不要接触眼睛,皮肤或衣服。
- P273 Avoid release to the environment. 避免释放到环境中。
- P501 Dispose of contents/container to..… 处理内容物/容器.....
|
Storage condition |
<0°C |
Hazard statements | |
- H303 May be harmfully swallowed 吞食可能有害
|
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Oral
SPECIES OBSERVED
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intraperitoneal
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 376 mg/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
IYKEDH Iyakuhin Kenkyu. Study of Medical Supplies. (Nippon Koteisho
Kyokai, 12-15, 2-chome, Shibuya, Shibuya-ku, Tokyo 150, Japan) V.1- 1970-
Volume(issue)/page/year: 20,228,1989
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Intramuscular
SPECIES OBSERVED : Rodent - rat
DOSE/DURATION : >2 gm/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
NIIRDN Drugs in Japan (Ethical Drugs). (Yakugyo Jiho Co., Ltd., Tokyo,
Japan) Volume(issue)/page/year: -,965,1990
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Oral
SPECIES OBSERVED : Mammal - dog
DOSE/DURATION : >200 mg/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
ARZNAD Arzneimittel-Forschung. Drug Research. (Editio Cantor Verlag,
Postfach 1255, W-7960 Aulendorf, Fed. Rep. Ger.) V.1- 1951-
Volume(issue)/page/year: 31,555,1981
TYPE OF TEST : LD50 - Lethal dose, 50 percent kill
ROUTE OF EXPOSURE : Oral
SPECIES OBSERVED : Rodent - mouse
DOSE/DURATION : 2454 mg/kg
TOXIC EFFECTS :
Details of toxic effects not reported other than lethal dose value
REFERENCE :
ARZNAD Arzneimittel-Forschung. Drug Research. (Editio Cantor Verlag,
Postfach 1255, W-7960 Aulendorf, Fed. Rep. Ger.) V.1- 1951-
Volume(issue)/page/year: 31,555,1981
TYPE OF
TYPE OF TEST : Mutation test systems - not otherwise specified
TEST SYSTEM : Rodent - hamster Liver
DOSE/DURATION : 2700 umol/L
REFERENCE :
EXPEAM Experientia. (Birkhaeuser Verlag, POB 133, CH-4010 Basel,
Switzerland) V.1- 1945- Volume(issue)/page/year: 46,461,1990
TYPE OF TEST : DNA inhibition
TEST SYSTEM : Human HeLa cell
DOSE/DURATION : 5 mmol/L
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 93,447,1982
TYPE OF TEST : Body fluid assay
TEST SYSTEM : Rodent - mouse Bacteria - Salmonella typhimurium
DOSE/DURATION : 1200 mg/kg
REFERENCE :
CNREA8 Cancer Research. (Public Ledger Building, Suit 816, 6th & Chestnut
Sts., Philadelphia, PA 19106) V.1- 1941- Volume(issue)/page/year:
38,4478,1978
TYPE OF TEST : Morphological transformation
TEST SYSTEM : Rodent - hamster Embryo
DOSE/DURATION : 50 umol/L
REFERENCE :
MUREAV Mutation Research. (Elsevier Science Pub. B.V., POB 211, 1000 AE
Amsterdam, Netherlands) V.1- 1964- Volume(issue)/page/year: 303,121,1993
TYPE OF TEST : Mutation in microorganisms
TEST SYSTEM : Bacteria - Salmonella typhimurium
DOSE/DURATION : 150 mg/L
REFERENCE :
ENMUDM Environmental Mutagenesis. (New York, NY) V.1-9, 1979-87. For
publisher information, see EMMUEG. Volume(issue)/page/year: 2,234,1980
GHS Symbol
Safety Statements | |
- S24/25 Avoid contact with skin and eyes 避免皮肤和眼睛接触;
|