安全信息
RTECS | NZ8175000 |
Safety Statements | |
- S26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice 眼睛接触后,立即用大量水冲洗并征求医生意见;
- S36/37/39 Wear suitable protective clothing, gloves and eye/face protection 穿戴适当的防护服、手套和眼睛/面保护;
- S24/25 Avoid contact with skin and eyes 避免皮肤和眼睛接触;
- S22 Do not breathe dust 不要吸入粉尘;
|
WGK Germany | 3 |
Personal Protective Equipment |
Eyeshields, Gloves |
Signal word |
Warning |
GHS Symbol
Risk Statements | |
- R36/37/38 Irritating to eyes, respiratory system and skin 对眼睛、呼吸系统和皮肤有刺激性
|
Storage condition |
极易吸潮,储存温度 2-8°C |
TYPE OF TEST : Cytogenetic analysis
TEST SYSTEM : Rodent - hamster Fibroblast
DOSE/DURATION : 2 pph
REFERENCE :
HDSKEK Hiroshima Daigaku Sogo Kagakubu Kiyo, 4: Kiso, Kankyo Kagaku Kenkyu.
Bulletin of the Faculty of Integrated Arts and Sciences, Hiroshima
University, Series 4: Fundamental and Environmental Sciences. (1-1-89
Higashisenda-machi, Naka-ku, Hiroshima 730, Japan) V.6- 1980-
Volume(issue)/page/year: 10,57,1985
TYPE OF TEST : Mutation in microorganisms
TEST SYSTEM : Bacteria - Salmonella typhimurium
DOSE/DURATION : 1 mg/plate
REFERENCE :
AMONDS Applied Methods in Oncology. (Elsevier Science Pub. Co., Inc., 52
Vanderbilt Ave., New York, NY 10017) V.1- 1978- Volume(issue)/page/year:
3,253,1980
TYPE OF TEST : Sister chromatid exchange
TEST SYSTEM : Rodent - hamster Fibroblast
DOSE/DURATION : 1 pph
REFERENCE :
HDSKEK Hiroshima Daigaku Sogo Kagakubu Kiyo, 4: Kiso, Kankyo Kagaku Kenkyu.
Bulletin of the Faculty of Integrated Arts and Sciences, Hiroshima
University, Series 4: Fundamental and Environmental Sciences. (1-1-89
Higashisenda-machi, Naka-ku, Hiroshima 730, Japan) V.6- 1980-
Volume(issue)/page/year: 10,57,1985
TYPE OF TEST : Cytogenetic analysis
TEST SYSTEM : Rodent - hamster Lung
DOSE/DURATION : 1 gm/L
REFERENCE :
AMONDS Applied Methods in Oncology. (Elsevier Science Pub. Co., Inc., 52
Vanderbilt Ave., New York, NY 10017) V.1- 1978- Volume(issue)/page/year:
3,253,1980